Fengfan Nanometer high anticorrosion protective agent FF-4310 is a two-component liquid coating built on a nanotechnology polymer system. It cures into a hard, ultra-thin film that is strongly hydrophobic and oleophobic, resists most chemicals including organic solvents, and lifts the salt-spray resistance of the part beneath it.
Metal finishers and OEMs use it as the closing step on parts that would otherwise go through a chromate bath. It bonds to glass, ceramics and engineering polymers as well as to steel, aluminium and plated surfaces, so one product covers components a metal-only treatment would miss, and it goes on by spray or brush at room temperature.
Fengfan supplies this protective agent to industrial metal plating operations, automotive and aerospace component makers, shipbuilders, electronics manufacturers and equipment builders in the nuclear and energy sectors — wherever a thin, clean barrier has to hold up against salt, moisture, chemical splash and mechanical wear.
| Test Item | Specification | Standard | Test Method |
| Appearance, component A | Colorless transparent liquid | — | Visual inspection |
| Appearance, component B | Colorless transparent liquid | — | Visual inspection |
| Nonvolatile content, % | 15±2 | GB1725 (method A) | GB1725, method A, on the A:B = 4:1 mixture |
| Density, g/cm³, component A | 0.80–0.85 | GB4472 | GB4472 |
| Density, g/cm³, component B | 0.78–0.82 | GB4472 | GB4472 |
| Product form | Two-component liquid | — | — |
| Application method | Spray or brush | — | — |
The film is built by a sol-gel process. Alkoxide precursors hydrolyse and condense on the surface, generating an inorganic network in place and, at the same time, growing an organic network alongside it. Because both networks form together, the cured material behaves neither as a pure glass nor as a pure polymer: it keeps the hardness and chemical inertness of the inorganic side while gaining the flexibility and substrate wetting of the organic side.
That structure is what makes the formulation tunable. The basic skeleton can be selected anywhere between a typical inorganic material and a typical organic one, and the balance shifts by adjusting the organic composition — more organic character for flexibility and wetting, more inorganic character for hardness and chemical resistance. For a specific part, the same chemistry can be pushed toward corrosion protection of a metal surface, toward scratch resistance on a polymer housing, or toward dust and dirt repellency.
Bonding is the second consequence of building the film this way. The sol-gel route creates chemical bonds to the substrate instead of relying on a keyed surface profile, so the film stays put through thermal cycling and mechanical handling rather than depending on a roughness the part may not have.
Salt air is the hardest test a protective film meets. In marine engineering and coastal infrastructure, metal components sit in a saline atmosphere that attacks edges, welds and fasteners first, and a coating that is merely water-resistant will not hold. This one is hydrophobic at the surface and chemically bonded at the interface, so salt-laden water beads and runs off instead of sitting on the part, and the film acts as a continuous barrier that slows rust progression rather than decorating the surface.
The maintenance cycle is where the saving shows. Salt deposits do not cling to a hydrophobic surface the way they cling to bare or conventionally finished steel, so the surface degrades more slowly and needs less frequent washing. On shipbuilding, offshore platform and harbour equipment programmes, that means fewer access hours, fewer touch-ups and less downtime for scaffolding or lifting gear.
Application matters as much as the film. Because the coating sprays or brushes on at room temperature, a yard can treat a finished structure, a deck fitting or a container frame in place, without dismantling it and without building a heated line to run it through.
Chromate treatments have been the default corrosion pretreatment for decades, and most shops keep them because requalifying a process is expensive. The pressure to change comes from the bath itself: chromate chemistry brings handling rules, rinse-water treatment and operator-exposure controls that get harder to live with each year.
This product takes a different route. The cured film contains no heavy metals, no fluorine and no phosphorus, so nothing in it carries a chromate-style hazard classification. Coating a part generates no wastewater, no waste residue and no waste gas discharge — the part goes in dry, comes out coated, and there is no rinse stream to treat afterwards.
There is also a step-count argument. On metal surfaces the coating needs no activation and no passivation before it goes on, so two stages drop out of the metal plating process, along with the tanks, the chemicals and the analysis time they consume. Everything runs at room temperature, which removes the heating load a hot chromate bath carries, and the step can sit alongside existing work without new capital equipment.
For the people running the line, the change is mostly about what disappears. There is no bath to analyse, no brightener to replenish and no rinse cascade to keep in balance — the coating is mixed, applied and left to cure, a much shorter sequence than a metal plating process demands. Operators work with a spray gun or a brush instead of a tank, and a part can be recoated or touched up without a new rack or a new process sheet.
Cleaning is the second saving. A hydrophobic, oleophobic surface does not hold dust, salt or oily film the way a bare or conventionally finished surface does, so parts cleaned before assembly, and equipment washed down on a maintenance schedule, need less of both. Less cleaning means less handling, and handling is where thin protective films usually get damaged.
The cost argument runs over the life of the part rather than the price of the drum. Every step removed from a plating process takes its chemicals, its analysis time and its waste stream with it, and a part that resists corrosion for longer does not come back for rework, replacement or a warranty claim. For a shop already carrying chromate waste treatment and exposure controls, the saving shows up in the effluent and compliance lines as much as on the production floor.
Choosing the right match is where most sourcing decisions stall. As a trading supplier, we keep one point of contact from first enquiry to after-sales: tell us what you are making and the conditions you work under, and we shortlist the closest matches from our supplier network, compare specifications and arrange samples before you commit to a bulk order. If something does not behave as expected, we work with the supplying partner on the cause and a practical fix, and stay with the case until it is settled. Email, WeChat or WhatsApp enquiries get a reply within 24 hours.
Metals, glass, ceramics and engineering polymers. The film forms by a sol-gel reaction that bonds chemically to the surface instead of keying into a roughened profile, so it holds on smooth glass and moulded plastics as well as on steel, aluminium and plated parts. If your part combines several materials, tell us the combination and we will confirm coverage for the whole assembly.
By doing the same job with a different chemistry. The cured film contains no heavy metals, fluorine or phosphorus, and coating a part produces no wastewater, waste residue or waste gas, so the chromate tank, its rinse cascade and its waste treatment come out of the line. The practical difference is that this is a coating rather than a conversion layer: adhesion depends on the surface being clean, dry and sound, and the film builds a few microns instead of etching into the metal.
The cured film is deliberately ultra-thin so machined, ground and threaded parts stay inside their dimensional tolerance. Within that constraint the formulation can be shifted: it combines inorganic and organic components, and changing the organic side moves the balance between hardness and chemical resistance on one hand, and flexibility and wetting on the other. Send us the substrate and the conditions the part will meet, and we will confirm what is achievable.
It is a two-component liquid, blended and then sprayed or brushed on at room temperature — no oven, no heated tank and no extra curing equipment, so parts can be coated at the end of a line or on site. The film forms at ambient temperature. The exact cure time, and whether a forced dry helps your handling schedule, depends on the substrate, film weight and how soon the parts must be packed; confirm that schedule with our technical contact before the first production run.
The cured film is transparent and only microns thick, so colour, laser marking, colour coding and surface finish stay readable underneath. Both components are colourless transparent liquids, which also makes uneven coverage easy to spot while you are applying. On decorative parts the visible change is in behaviour rather than appearance — water and oil stop wetting the surface, and dust wipes off more easily.