Butynediol propoxylate is an alkynol brightener and leveling agent for nickel electroplating baths. It arrives as a liquid intermediate and is added at a low rate alongside the carrier, the wetting agent and the other brightener components that make up a working nickel package.
Bright nickel plating is where most of it goes. The deposit has to come out glossy across the whole part — on the faces that sit closest to the anode and in the recesses that see the least current — and it has to stay that way through a long production run instead of dulling after a shift or two. This grade works on both halves of that job: it lifts the gloss, and it levels, smoothing the fine roughness that would otherwise be cut back on a polishing wheel.
Placement matters. The product belongs to electro nickel plating, not to the electroless line: the addition goes into the nickel electrolyte itself, and the working figure is set on the bath you actually run rather than copied from another shop's process sheet.
Buyers are usually decorative plating shops, formulators who blend their own brightener systems, and distributors stocking intermediates for a region.
| Item | Technical index |
|---|---|
| Product name | Butynediol propoxylate |
| Synonym | BMP |
| CAS No. | 1606-79-7 |
| Molecular formula | C10H18O4 |
| Molecular weight | 144.17 |
| Appearance | Yellowish to yellow transparent liquid |
| Assay | 95%min |
| Density, g/cm³ (20 °C) | 1.05–1.10 |
| pH | 5.0~7.0 |
| Refractive index (20 °C) | 1.4640–1.4726 |
| Product function | Brightener and leveling agent for decorative and wear-resistant nickel plating baths |
| Supplied form | Liquid, weighed or metered straight into the bath |
| Package | 25 kg plastic drum |
Decorative bright nickel plating is the main home for this grade. Steel, brass and zinc die castings going through a copper–nickel–chrome sequence are the classic case: the nickel layer carries the gloss, and a level deposit means less buffing between the nickel and the chrome.
Job shops that supply nickel plating services on a mixed order book use it the same way from one order to the next — the product does not care what the part is, only how the bath is running.
It is not an electroless product. Lines that also run electroless nickel plating services keep that chemistry and its additives separate, and this grade stays on the electrolytic side.
Functional parts use it too. Where the nickel is specified as wear-resistant nickel plating rather than for show, the leveling action still matters: it holds an even deposit across the part, and uneven thickness is where wear and corrosion start first.
Treat it as a concentrated additive. Wear the gloves and eye protection named on the safety data sheet, keep the drum closed between additions, keep ventilation running where the bath is made up, and do not decant into an unlabelled bottle.
Store drums in a cool, dry, ventilated area out of direct sunlight, with the original label and batch number on the container. Rotate stock so the oldest drum is used first, and keep drums off a damp floor.
Before the first delivery, ask your sales contact for the safety data sheet for your market and keep a copy where the drums are stored. If a drum arrives with a damaged closure or a label you cannot read, set it aside and tell us rather than adding it to a bath.
Shops that run more than one finishing line often buy several intermediates from the same place. Alongside this nickel brightener, the range covers the SZ-30B brightener system for sulphate acid zinc plating, ZN 50 bright zinc for rack and barrel work, the ZN-500 brightener for cyanide-free alkaline zinc plating, the Phoenix EB 204A-204B divalent tin salt electrolytic colouring additive, the Phoenix Seal 149-L and 149-T mid-temperature sealing agents for aluminium anodizing, the FI-970 bright acid copper process, FF-4219 wood, stone and concrete nano-protective, Nickel Purify P3, and the FF-116 environmentally friendly chrome mist inhibitor.
Buyers who run several of these lines usually put them on one order, placed direct or through the nickel plating company or distributor they already buy from, so the paperwork and the delivery dates stay together.
Choosing the right match is where most sourcing decisions stall. As a trading supplier, we keep one point of contact from first enquiry to after-sales: tell us what you are making and the conditions you work under, and we shortlist the closest matches from our supplier network, compare specifications and arrange samples before you commit to a bulk order. If something does not behave as expected, we work with the supplying partner on the cause and a practical fix, and stay with the case until it is settled. Email, WeChat or WhatsApp enquiries get a reply within 24 hours.
No. It is an electrolytic brightener and leveling agent, added to the nickel electrolyte itself, while baths run for electroless nickel plating services deposit by chemical reduction and need a different additive package. Keep the two chemistries and their additives apart even when both lines sit in the same shop.
Yes, as one component. The product goes into the electro nickel plating bath as part of the package you already use; leave the rest of that package unchanged during the trial so you can see what this one does. Confirm the working figure on your own bath before the addition reaches production.
It levels as well as brightens. The leveling action evens out micro-roughness so the deposit reads flat rather than following the shape of the part, which is why decorative lines polish less after nickel. The brightening side lifts gloss at the same time.
Compare it against your retained sample. Colour and clarity are the two things to look at, and a clear bottle side by side shows a shift straight away. If a delivery looks different from what you normally receive, hold the drum and check with your sales contact before it enters the plating process.
Send the CAS number, 1606-79-7, the assay you work to and the name of your current product. A formulator or a nickel plating company can put the two data sheets side by side; molecular formula, molecular weight, density and refractive index either line up or they do not, and that comparison takes a few minutes. Where you are switching from another butynediol grade, confirm the match on a hull cell panel before the drum goes into production.